- Up to 15% off
Matt
Matt Ortho IPR Contra Angle Ortho Strips HD 1 piece
In stock (542 units)Sale price LE 280.00 EGP Regular price LE 330.00Unit price /Unavailable Matt
Matt Ortho Stripping stainless diamond double sided 1 piece
In stock (185 units)Regular price LE 77.00 EGPUnit price /UnavailableMatt
Matt Ortho Stripping stainless diamond single sided 1 piece
In stock (94 units)Regular price LE 75.00 EGPUnit price /UnavailableMatt
Very low stock (6 units)Sale price LE 600.00 EGP Regular price LE 660.00Unit price /UnavailableIntensiv
Very low stock (8 units)Regular price LE 325.00 EGPUnit price /UnavailableIntensiv
Low stock (9 units)Regular price LE 940.00 EGPUnit price /UnavailableIntensiv
Low stock (10 units)Regular price LE 2,450.00 EGPUnit price /UnavailableMatt
Matt Ortho Stripping kit contra angle LOW SPEED Handpiece 4:1 kit
Very low stock (5 units)Sale price LE 9,890.00 EGP Regular price LE 10,990.00Unit price /Unavailable
How to Choose the Right IPR Strip System for Your Case
- Diamond Grit Selection — Fine, medium, and coarse diamond grit strips remove enamel at different rates per pass; coarser grit is used for the initial reduction pass and finer grit for final contour refinement.
- Single-Sided vs Double-Sided Coating — Single-sided diamond strips protect the adjacent tooth surface during an initial, directional pass, while double-sided strips allow efficient bilateral reduction of both contact surfaces in one motion.
- Manual Handle vs Contra-Angle Mounting — A contra-angle-mounted strip (e.g. Matt Ortho HD) is driven by a handpiece for faster, more consistent oscillating reduction, while a manual handle gives the clinician direct tactile control for smaller or more precise adjustments.
- Strip Width and Thickness — Thinner strips access tight, pre-treatment contacts more easily, while wider strips are used once initial space has been created to refine broader interproximal surfaces.
- Safe Enamel Removal Limit — Orthodontic literature generally supports removing no more than approximately 0.5mm of enamel per contact per arch, distributed across multiple visits rather than in a single aggressive pass.
- Post-IPR Finishing — Polishing and topical fluoride application after stripping smooths the reduced surface and reduces the risk of increased demineralisation or plaque retention at the treated contact.
IPR Strip Types at a Glance
| Product | Coating | Mounting |
|---|---|---|
| Matt Ortho IPR Contra-Angle Strip HD | Diamond, double-sided | Contra-angle handpiece |
| Matt Ortho Diamond Strip (single-sided) | Diamond, single-sided | Manual handle |
| Matt Ortho Diamond Strip (double-sided) | Diamond, double-sided | Manual handle |
| Intensiv Proxo Strip | Abrasive-coated | Manual |
| Matt Ortho IPR Manual Handle | N/A (strip holder) | Manual |
Availability & Delivery in Egypt
MedSTA supplies manual and contra-angle-mounted IPR stripping systems in EGP with nationwide delivery to orthodontic practices across Egypt.
Frequently Asked Questions
What is the difference between single-sided and double-sided diamond stripping strips?
What is the difference between single-sided and double-sided diamond stripping strips?
Single-sided strips carry diamond abrasive on one face only, protecting the adjacent tooth surface during a directional first pass. Double-sided strips are coated on both faces, allowing both contact surfaces of the gap to be reduced simultaneously for faster, more efficient stripping once the initial pass is complete.
How much enamel can safely be removed during interproximal reduction?
How much enamel can safely be removed during interproximal reduction?
Most orthodontic protocols limit total interproximal enamel removal to approximately 0.5mm per contact per arch, distributed across several visits rather than removed in a single session, to avoid weakening enamel or increasing sensitivity.
When should a mechanised contra-angle stripping system be used instead of a manual handle?
When should a mechanised contra-angle stripping system be used instead of a manual handle?
A contra-angle-mounted strip is preferred for faster, more consistent reduction across multiple contacts in a single appointment, since the handpiece drives a controlled oscillating motion. A manual handle gives more direct tactile feedback and is often preferred for fine contouring or very tight initial contacts.
Should teeth be polished or given fluoride after interproximal stripping?
Should teeth be polished or given fluoride after interproximal stripping?
Yes. Polishing the stripped surface smooths any residual roughness from the abrasive strip, and a topical fluoride application afterward helps reduce sensitivity and lowers the risk of increased demineralisation at the newly exposed interproximal enamel.
Does MedSTA supply manual and contra-angle IPR stripping systems across Egypt?
Does MedSTA supply manual and contra-angle IPR stripping systems across Egypt?
Yes. MedSTA supplies manual and contra-angle-mounted diamond stripping strips from Matt Ortho and Intensiv, priced in EGP with nationwide delivery to orthodontic practices across Egypt.