Elephant
Elephant Dental Compressor – Auto Evacuation System
Low stock (11 units)Regular price From LE 7,750.00 EGPUnit price /UnavailableGENERIC
Low stock (9 units)Regular price LE 3,299.00 EGPUnit price /UnavailableGENERIC
Low stock (10 units)Regular price LE 65.00 EGPUnit price /UnavailableGENERIC
Low stock (10 units)Regular price LE 4,099.00 EGPUnit price /UnavailableGENERIC
Zimport Compressor 40L-head 850W
Low stock (10 units)Regular price LE 8,499.00 EGPUnit price /UnavailableDS
Very low stock (5 units)Regular price LE 24,500.00 EGPUnit price /UnavailableDS
Very low stock (5 units)Regular price LE 15,900.00 EGPUnit price /UnavailableDS
Very low stock (5 units)Regular price LE 8,500.00 EGPUnit price /UnavailableZafdent
Very low stock (5 units)Regular price LE 38,500.00 EGPUnit price /UnavailableZafdent
Low stock (10 units)Regular price LE 12,000.00 EGPUnit price /Unavailable
Choosing the Right Dental Air Compressor
- Oil-Free vs Oil-Lubricated — Oil-free compressors are mandatory for dental use -- oil-lubricated compressors risk contaminating the air supply and damaging handpiece turbines. All ISO-compliant dental installations require oil-free compressors; oil vapour contamination is also a patient safety risk that regulators in Egypt's Ministry of Health monitor.
- Tank Size — Single-surgery clinics require a minimum 24-litre tank; multi-surgery (3+ chairs) require 90-150 litres. Undersized tanks cause compressor duty-cycle problems -- the motor runs continuously to keep up with demand, reducing motor lifespan significantly.
- CFM / FAD Output — Free Air Delivery (FAD) in litres per minute must exceed total handpiece consumption by 20% to avoid pressure drop during simultaneous use. A standard air-turbine handpiece uses 60-80 L/min; a micromotor uses 30-50 L/min. Two simultaneous chairs need at minimum 200 L/min FAD.
- Noise Level — Silent dental compressors operate below 55 dB -- essential for patient comfort in open-plan Egyptian clinic environments. Wall-mounted silent compressors in a utility room further reduce noise impact; direct operatory mounting is not recommended even at 55 dB.
- Medical Grade Certification — Specify ISO 7396-1 compliant medical air compressors for multi-surgery and hospital dental setups in Egypt. ISO 7396-1 mandates redundant compressors, an air quality monitoring panel, and validated oil and particulate filtration for medical installations.
- Maintenance — Oil-free compressors require filter cartridge replacement every 2,000 operating hours and annual valve inspection. Keep a maintenance log -- filters degrade gradually rather than failing suddenly, and contaminated filters allow water vapour and particulates into handpieces.
Dental Air Compressor Specifications
| Technical Property | Single Surgery | 3-Surgery Clinic | Hospital Unit |
|---|---|---|---|
| Tank Volume | 24 litres | 90 litres | 150+ litres |
| FAD Output | 100-120 L/min | 200-250 L/min | 400+ L/min |
| Noise Level | Below 55 dB | Below 58 dB | Plant room install |
| Motor Type | Oil-free piston | Oil-free twin-piston | Oil-free scroll |
| ISO Standard | ISO 8573-1 | ISO 8573-1 | ISO 7396-1 (medical) |
How to Select a Dental Air Compressor
- Count the number of active dental chairs to determine FAD and tank requirements.
- Specify oil-free type -- oil-lubricated compressors are not acceptable for dental use.
- Calculate total handpiece air consumption per chair; multiply by chairs and add 20% headroom.
- Choose a silent model (below 55 dB) if the compressor is installed in or near the clinical area.
- For multi-surgery or hospital setups, require ISO 7396-1 medical air certification.
Availability & Delivery in Egypt
MedSTA supplies dental air compressors to Egyptian clinics in single and multi-surgery capacities with EGP pricing and nationwide delivery. Oil-free, silent models suitable for Egyptian clinic standards.
Frequently Asked Questions
Why does a dental clinic need an oil-free compressor?
Why does a dental clinic need an oil-free compressor?
Oil-lubricated compressors contaminate the air supply, damaging handpiece turbines and posing a patient safety risk.
What tank size do I need for a 2-surgery dental clinic?
What tank size do I need for a 2-surgery dental clinic?
A minimum 50-90 litre tank for a 2-chair clinic; calculate FAD based on handpiece air consumption per chair.
How loud should a dental compressor be?
How loud should a dental compressor be?
Below 55 dB for operatory or near-clinical installation -- silent models are standard in modern Egyptian clinic design.
What is FAD in dental compressors?
What is FAD in dental compressors?
Free Air Delivery (L/min) -- the actual air volume output; must exceed total handpiece consumption by 20% headroom.
What maintenance does a dental compressor need?
What maintenance does a dental compressor need?
Filter cartridge replacement every 2,000 hours and annual valve inspection -- log all maintenance for infection control records.
What is ISO 7396-1 for dental compressors?
What is ISO 7396-1 for dental compressors?
The ISO standard for medical air systems in hospitals and multi-surgery clinics, requiring redundancy and air quality monitoring.
Are dental compressors available in Egypt from MedSTA?
Are dental compressors available in Egypt from MedSTA?
Yes -- single and multi-surgery oil-free compressors in EGP with nationwide delivery across Egypt.